These faults were reported to have occurred on a D.C. Motor.
a. Failure to start.
b. Sparking brushes.
S/No | FAULT | CAUSE | REMEDY |
(a) | Failure to start | i. Open circuit on starter resistance. Ii. Open circuit on-field circuit. | Change the starter resistance. Rewind the field winding. |
(b) | Sparking at brushes. | (i) Open circuit. (ii) Shorted or earthed armature coil. (iii) Wrong brush position. (iv) Motor overloaded. (v) Dirty or worn out commutator. | Proper connection Proper lamination and insulation. Proper position. Reduce the load. Clean the commutator or replace the commutator. |